PRINT ALL

PGC-150 Gas Chiller

PGC-150 Specs:
DescriptionPGC-150
Temperature Range (°C)-90 to -125
Temperature Range (°F)-130 to -193
Maximum Flow Rate (LPM)354
Maximum Flow Rate (SCFH)750
Test Load (SCFH)450
Loaded Discharge Temp (°C)<115
Loaded Suction Pressure (psig)25 to 35
Loaded Discharge Pressure (psig)225 to 255
Loaded Gas Outlet Temp (°C)<=-97
Maximum Gas Source Temp (°C)30
Maximum Condenser Air Inlet Temp (°C)32
Option "W" Cooling Water l/min. [gal/min.] @ 26°C4.3 [1.1]
Option "W" Cooling Water Connections1/2" FNPT
Gas In/Out Tubing Diameter mm [in.]9.5 [3/8]
Unit Weight kg [lb]108 [240]
Dimensions Width x Depth x Height (mm)508 x 457 x 889
Dimensions Width x Depth x Height (in.)20 x 18 x 35
Voltage Range @ 60Hz187-253
Full Load Amps @ 230V12.5
Full Load Power Input (kVA)2.9
Fuse Size Amps @ 230V20
Max Operating Sound Level (dB)<70
Loaded specifications are based on Factory Tests at specified load point. Water flow rate requirements vary, depending upon water coolant supply temperature (see instruction manual for flow rates at other temperatures).

PGC-150 Gas Exit Temp (°C) vs. Gas Flow
Option "T"  =  Gas Control Valve, Flow Switch, EMO
Option "W" =  Water Cooled Operation
Operating specs are the same for the PGC-150 and
the PGC-150CE/S2. The difference is in the electrical
control and safety systems.
DescriptionPart NumberUsed Unit Price (USD)
PGC-150MT-0405Unit Base Price= $4,500.00
PGC-150CE/S2MT-0437Unit Base Price= $6,000.00
Top HatOPTION "T"(Add to Base Price) $500.00
Water CooledOPTION "W"(Add to Base Price) $500.00
Specify Desired Unit Voltage When Placing Order

Prices subject to change without notice, FOB M&T Systems Factory, Effective date January, 2010.
Some exceptions apply.

PFC-200 Water Vapor Cryopump

PFC-200 Specs:
Description200ST200HT
Temperature Range (°C)-100 to -140-100 to -140
Temperature Range (°F)-148 to -220-148 to -220
Tested Heat Load (Watts)200400
Loaded Liquid Line Temp (°C)22 to 25
Loaded Discharge Temp (°C)<120<123
Loaded Suction Pressure (psig)18 to 2918 to 35
Loaded Discharge Pressure (psig)<220<260
Loaded Coil-In Temp (°C)<=-130<=-120
Loaded Coil-Out Temp (°C)<=-116<=-98
Defrost Time (minutes)<4
Pumping Speed (l/sec)20,000
Ultimate Vacuum (torr)2x10-8
Total Cryocoil Surface Area m2 [ft.2]0.2 [2.2]
Cooling Water l/min. [gal/min.] @ 26°C8.9 [2.3]
Cooling Water Connections1/2" FNPT
Unit Weight kg [lb]204 [450]
Dimensions Width x Depth x Height (mm)610 x 559 x 1397
Dimensions Width x Depth x Height (in.)24 x 22 x 55
Voltage Range @ 60Hz 230V [460V]187-253 [414-506]
Full Load Amps 230V [460V]16 [8]
Full Load Power Input (kVA)6.4
Fuse Size Amps 230V [460V]30 [15]
Max Operating Sound Level (dB)73
Loaded specifications are based on Factory Tests at specified load point. Water flow rate requirements vary, depending upon water coolant supply temperature (see instruction manual for flow rates at other temperatures).

PFC-200 Cryosurface Temp (°C) vs. Load
When originally developed, the 200 Series was thought to be only suitable for loads of up to 200 Watts. Later it was discovered through charge improvements that the capacity could be doubled to 400 Watts.

So both the ST (Standard) and the HT (High Torr) series units are actually one in the same. With less load we simply see colder cryocoil temperatures.
DescriptionPart NumberUsed Unit Price (USD)
P-200STMT-0406Unit Base Price= $4,000.00
PFC-200STMT-0407Unit Base Price= $4,500.00
HT Version (newer)OPTION "H"(Add to Base Price) $1,000.00
Specify Desired Unit Voltage When Placing Order

Prices subject to change without notice, FOB M&T Systems Factory, Effective date January, 2010.
Some exceptions apply.

PFC-330 Water Vapor Cryopump

PFC-330 Specs:
DescriptionPFC-330
Temperature Range (°C)-100 to -140
Temperature Range (°F)-148 to -220
Tested Heat Load (Watts)400
Loaded Liquid Line Temp (°C)22 to 25
Loaded Discharge Temp (°C)<125
Loaded Suction Pressure (psig)25 to 40
Loaded Discharge Pressure (psig)<325
Loaded Coil-In Temp (°C)<=-135
Loaded Coil-Out Temp (°C)<=-113
Defrost Time (minutes)<3
Pumping Speed (l/sec)20,000
Ultimate Vacuum (torr)2x10-8
Total Cryocoil Surface Area m2 [ft.2]0.2 [2.2]
Cooling Water l/min. [gal/min.] @ 26°C8.9 [2.3]
Cooling Water Connections1/2" FNPT
Unit Weight kg [lb]211 [465]
Dimensions Width x Depth x Height (mm)610 x 559 x 1659
Dimensions Width x Depth x Height (in.)24 x 22 x 65
Voltage Range @ 60Hz 230V [460V]187-253 [414-506]
Full Load Amps 230V [460V]16.5 [8.3]
Full Load Power Input (kVA)6.6
Fuse Size Amps 230V [460V]30 [15]
Max Operating Sound Level (dB)73
Loaded specifications are based on Factory Tests at specified load point. Water flow rate requirements vary, depending upon water coolant supply temperature (see instruction manual for flow rates at other temperatures).

PFC-330 Cryosurface Temp (°C) vs. Load
The PFC-330 was created to take the place of the aging PFC-400 series units, by adding an updated electronic control and safety system, as well as superior cooling and defrost performance improvements. Presently this is the only Polycold unit that provides a digital pressure read-out.

Although an "LT" version of the 330 was in the works, it was never completed, and instead Polycold continued to use the PFC-400LT to fill the low temperature requirement instead.

The PFC-340 was the newest iteration in the 300 series, and is identical to PFC-330 with the exception of a colder defrost termination point (0-5 °C) and the addition of a Buffer Un-Loader Cable. With these changes, the PFC-340 tends to have an improved MTBF.
DescriptionPart NumberUsed Unit Price (USD)
PFC-330MT-0408Unit Base Price= $7,000.00
PFC-340MT-0409Unit Base Price= $9,000.00
Specify Desired Unit Voltage When Placing Order

Prices subject to change without notice, FOB M&T Systems Factory, Effective date January, 2010.
Some exceptions apply.

PFC-400 Water Vapor Cryopump

PFC-400 Specs:
Description400HC400LT
Temperature Range (°C)-100 to -140-130 to -150
Temperature Range (°F)-148 to -220-202 to -238
Tested Heat Load (Watts)400200
Loaded Liquid Line Temp (°C)22 to 25
Loaded Discharge Temp (°C)<123<124
Loaded Suction Pressure (psig)18 to 3527 to 33
Loaded Discharge Pressure (psig)<260<290
Loaded Coil-In Temp (°C)<=-120<=-142
Loaded Coil-Out Temp (°C)<=-98<=-126
Defrost Time (minutes)<4
Pumping Speed (l/sec)20,000
Ultimate Vacuum (torr)2x10-84x10-10
Total Cryocoil Surface Area m2 [ft.2]0.2 [2.2]
Cooling Water l/min. [gal/min.] @ 26°C8.9 [2.3]
Cooling Water Connections1/2" FNPT
Unit Weight kg [lb]204 [450]
Dimensions Width x Depth x Height (mm)610 x 559 x 1397
Dimensions Width x Depth x Height (in.)24 x 22 x 55
Voltage Range @ 60Hz 230V [460V]187-253 [414-506]
Full Load Amps 230V [460V]16 [8]
Full Load Power Input (kVA)6.4
Fuse Size Amps 230V [460V]30 [15]
Max Operating Sound Level (dB)73
Loaded specifications are based on Factory Tests at specified load point. Water flow rate requirements vary, depending upon water coolant supply temperature (see instruction manual for flow rates at other temperatures).

PFC-400 Cryosurface Temp (°C) vs. Load
This unit series was based on the PFC-200 design and shared many common parts. It was considered to be a minor upgrade, only making some small changes to the overall packaging, and introducing a new "LT" version charge.

Although there was an "ST" version of the PFC-400, it was only manufactured for a very short time, and is considered to be the same as its "HC" counter part ("ST" specifications were identical to the PFC-200ST).
DescriptionPart NumberUsed Unit Price (USD)
P-400MT-0410Unit Base Price= $5,500.00
PFC-400MT-0411Unit Base Price= $6,000.00
LT VersionOPTION "L"(No Additional Cost)
Specify Desired Unit Voltage When Placing Order

Prices subject to change without notice, FOB M&T Systems Factory, Effective date January, 2010.
Some exceptions apply.

PFC-550 Water Vapor Cryopump

PFC-550 Specs:
Description550ST550HC550LT
Temperature Range (°C)-100 to -140-100 to -140-140 to -157
Temperature Range (°F)-148 to -220-148 to -220-220 to -250
Tested Heat Load (Watts)6501000400
Loaded Liquid Line Temp (°C)22 to 25
Loaded Discharge Temp (°C)<121<124<124
Loaded Suction Pressure (psig)15 to 2215 to 2615 to 28
Loaded Discharge Pressure (psig)<220<265<246
Loaded Coil-In Temp (°C)<=-128<=-116<=-154
Loaded Coil-Out Temp (°C)<=-115<=-103<=-126
Defrost Time (minutes)<3
Pumping Speed (l/sec)50,00050,00025,000
Ultimate Vacuum (torr)2x10-82x10-85x10-11
Total Cryocoil Surface Area m2 [ft.2]0.5 [5.4]0.5 [5.4]0.25 [2.7]
Cooling Water l/min. [gal/min.] @ 26°C12.3 [3.2]
Cooling Water Connections1/2" FNPT
Unit Weight kg [lb]408 [900]
Dimensions Width x Depth x Height (mm)953 x 660 x 1842
Dimensions Width x Depth x Height (in.)37.5 x 26 x 72.5
Voltage Range @ 60Hz 230V [460V]187-253 [414-506]
Full Load Amps 230V [460V]32 [16]
Full Load Power Input (kVA)12.7
Fuse Size Amps 230V [460V]50 [25]
Max Operating Sound Level (dB)71
Loaded specifications are based on Factory Tests at specified load point. Water flow rate requirements vary, depending upon water coolant supply temperature (see instruction manual for flow rates at other temperatures).

PFC-550 Cryosurface Temp (°C) vs. Load
When originally developed, the 550 Series was thought to be limited to a maximum heat load capacity of 650 Watts. Later it was discovered through charge improvements, that the performance could be increased by 55%, yielding a total heat load capacity of 1000 Watts.

So both the ST (Standard) and the HC (High Capacity) series units are actually one in the same. With less load we simply see colder cryocoil temperatures.

Eventually a new Low Temperature (LT) charge was devised, which allowed the PFC-550LT to run at much lower temperatures than it's "ST" and "HC" counter parts. Thus making it suitable for the ultra high vacuum coating system market.
DescriptionPart NumberUsed Unit Price (USD)
P-550STMT-0414Unit Base Price= $9,500.00
PFC-550STMT-0415Unit Base Price= $10,000.00
HC Version (newer)OPTION "H"(Add to Base Price) $2,000.00
LT VersionOPTION "L"(No Additional Cost)
Specify Desired Unit Voltage When Placing Order

Prices subject to change without notice, FOB M&T Systems Factory, Effective date January, 2010.
Some exceptions apply.

PFC-660 Water Vapor Cryopump

PFC-660 Specs:
Description660ST660HC
Temperature Range (°C)-100 to -140-100 to -140
Temperature Range (°F)-148 to -220-148 to -220
Tested Heat Load (Watts)8501500
Loaded Liquid Line Temp (°C)22 to 25
Loaded Discharge Temp (°C)<115<120
Loaded Suction Pressure (psig)20 to 2820 to 35
Loaded Discharge Pressure (psig)<210<265
Loaded Coil-In Temp (°C)<=-127<=-119
Loaded Coil-Out Temp (°C)<=-113<=-104
Defrost Time (minutes)<3
Pumping Speed (l/sec)70,000
Ultimate Vacuum (torr)6x10-9
Total Cryocoil Surface Area m2 [ft.2]0.7 [7.5]
Cooling Water l/min. [gal/min.] @ 26°C17.3 [4.6]
Cooling Water Connections1/2" FNPT
Unit Weight kg [lb]478 [1055]
Dimensions Width x Depth x Height (mm)953 x 660 x 1842
Dimensions Width x Depth x Height (in.)37.5 x 26 x 72.5
Voltage Range @ 60Hz 230V [460V]187-253 [414-506]
Full Load Amps 230V [460V]32 [16]
Full Load Power Input (kVA)12.7
Fuse Size Amps 230V [460V]50 [25]
Max Operating Sound Level (dB)72
Loaded specifications are based on Factory Tests at specified load point. Water flow rate requirements vary, depending upon water coolant supply temperature (see instruction manual for flow rates at other temperatures).

PFC-660 Cryosurface Temp (°C) vs. Load
When originally developed, the 660 Series was thought to be limited to a maximum heat load capacity of 850 Watts. Later it was discovered through charge improvements, that the performance could be increased by 78%, yielding a total heat load capacity of 1500 Watts.

So both the ST (Standard) and the HC (High Capacity) series units are actually one in the same. With less load we simply see colder cryocoil temperatures.

The PFC-660HC turned out to be a very reliable work horse in the medium-to-high wattage extremes, while still producing very cold temperatures under low load conditions. In fact it possesses nearly 40% more water pumping capacity than a PFC-550HC, while consuming nearly the same amount of electrical energy.
DescriptionPart NumberUsed Unit Price (USD)
P-660STMT-0418Unit Base Price= $11,500.00
PFC-660STMT-0419Unit Base Price= $12,000.00
2 Circuit ConfigurationOPTION "2"(Add to Base Price) $2,000.00
HC Version (newer)OPTION "H"(Add to Base Price) $2,000.00
Specify Desired Unit Voltage When Placing Order

Prices subject to change without notice, FOB M&T Systems Factory, Effective date January, 2010.
Some exceptions apply.

PFC-1100 Water Vapor Cryopump

PFC-1100 Specs:
Description1100ST1100HC1100LT
Temperature Range (°C)-100 to -140-100 to -140-140 to -160
Temperature Range (°F)-148 to -220-148 to -220-220 to -256
Tested Heat Load (Watts)15003600800
Loaded Liquid Line Temp (°C)22 to 25
Loaded Discharge Temp (°C)<122<124<124
Loaded Suction Pressure (psig)20 to 3035 to 4520 to 35
Loaded Discharge Pressure (psig)<255<375<310
Loaded Coil-In Temp (°C)<=-124<=-102<=-152
Loaded Coil-Out Temp (°C)<=-113<=-94<=-135
Defrost Time (minutes)<3
Pumping Speed (l/sec)200,000200,00050,000
Ultimate Vacuum (torr)6x10-96x10-81x10-12
Total Cryocoil Surface Area m2 [ft.2]2.0 [21.6]2.0 [21.6]0.5 [5.4]
Cooling Water l/min. [gal/min.] @ 26°C33.8 [8.9]
Cooling Water Connections3/4" FNPT
Unit Weight kg [lb]544 [1200]
Dimensions Width x Depth x Height (mm)1054 x 711 x 1689
Dimensions Width x Depth x Height (in.)41.5 x 28 x 66.5
Voltage Range @ 60Hz 230V [460V]187-253 [414-506]
Full Load Amps 230V [460V]45 [22]54 [27]45 [22]
Full Load Power Input (kVA)17.921.517.9
Fuse Size Amps 230V [460V]70 [35]80 [40]70 [35]
Max Operating Sound Level (dB)81
Loaded specifications are based on Factory Tests at specified load point. Water flow rate requirements vary, depending upon water coolant supply temperature (see instruction manual for flow rates at other temperatures).

PFC-1100 Cryosurface Temp (°C) vs. Load
The 1100 Series has 3 distinct capacity classes, and unlike the other Polycold units, physical changes were required to obtain the "ST" to "HC" load handling improvements.

So although it is possible with a simple charge replacement to convert an "ST" unit into an "LT", or an "LT" unit into an "ST", it's just not possible to convert an "ST" or an "LT" into an "HC" unit by this same process. The reverse situation, converting an "HC" unit into an "ST" or "LT", would also require physical alterations.

When it comes to maximum cooling power, nothing beats a PFC-1100HC, with over twice the heat load capability and water pumping speed of either a PFC-660HC or an 1100ST. It truly is the monster of any Polycold ever built.
DescriptionPart NumberUsed Unit Price (USD)
P-1100STMT-0422Unit Base Price= $15,500.00
PFC-1100STMT-0423Unit Base Price= $16,000.00
2 Circuit ConfigurationOPTION "2"(Add to Base Price) $2,000.00
HC Version (newer)OPTION "H"(Add to Base Price) $2,000.00
LT VersionOPTION "L"(No Additional Cost)
Specify Desired Unit Voltage When Placing Order

Prices subject to change without notice, FOB M&T Systems Factory, Effective date January, 2010.
Some exceptions apply.